– Dual passive infrared + dual MW channel
– Range from 15 to 23 m
– Coverage from 5° to 90° m (optional lens included)
– ANTI-MASKING function with ACTIVE INFRARED
– PET Immunity
– Frequency: 10,525 GHz
– Consumption : 65-77 mA
– Power supply: 13.8 Vdc
– Protection tamper against cover opening
– Protection tamper against removal from the wall
– Alarm relay at positive security
– RS485 serial for communication to AVS systems
– USB port of programming
– Walk-test LED and Buzzer
– Predisposition for location of a camera
– Working temperature: -25 C° + 55 C°
– Dimensions (DxLxH) 135 x 140 x 240 mm
Protection class: IP 65
Detection type | Double PIR sensor |
---|---|
90° coverage 2.2 m height | 15 meters |
5° coverage 2.2 m height | 23 meters |
90° coverage 1.2 m height | 15 meters |
Installation height | From 1 up to 2.7 meters |
Fixing bracket | Included |
Immunity to animals | Yes |
Nominal voltage | 12 V |
Minimum voltage | 11.5 V |
Maximum voltage | 15 V |
Standby consumption | 53 mA |
Consumption during alarm | 67 mA |
Dimensions: (D x W x H) cm | 9.5 x 10.5 x 23.5 |
Dimensions with cap (D x W x H) cm | 13.5 x 14 x 24 |
Lock input | It is possible to block the microwave thanks to the dedicated “B” input, when the control panel is disarmed. |
Auxiliary input | Negative input for extra information |
Alarm output | Normally closed (C/NC) |
Antimask output | Normally closed (C/NC) for antimasking information |
Dirty lens output | Transistorised output for dirty lens information |
Tamper output | Normally closed (C/NC) |
Walk test and calibration | Led and buzzer – with SMART EDITION |
Serial output – RS485 | Yes |
USB Output | Yes – with optional cable mod. USB-OUT |
Selectable serial addresses | 32 |
Events memory | Up to 1920 events memorised with date and time – waveforms – working temperature |
Blocks memorisation with - system disarmed | Yes |
Environmental conditions | from -20°C to +55°C |
IP Level | IP 65 |
Compliant RF Standard | yes |