Works with the RX-20 receiver model.
VIP Pro wireless detector provides highly reliable movement detection and ensures excellent protection against any attempt to disable its operation by blocking (masking) its near field-of-view or when the detector has been covered, whether the alarm system is armed or disarmed (Anti-Masking).
Highly reliable movement detection is achieved by combining two PIR synchronised sensors, which allow three-dimensional thermal imaging of the protected area. The analogue signal received from each sensor is converted to digital signals and separately processed by a powerful Microprocessor.
Movement alarm will be generated only if each of the sensors received a true detection signal. Each sensor’s sensitivity can be adjusted separately by a trimmer.
Shutters Behind The Lens
Enable narrowing the vertical detector’s PIR field-of-view.
Behind the detector’s lens, there is a support that consists of shutters placed above both PIR sensors. By opening or closing the shutters you can limit the vertical angle of the PIR field-of-view.
Tilt Plates
Enable mount the detector on an angle.
To mount (install) the detector directly on a wall or any other flat surface and provide the detector with a slight vertical tilt (upward or downward) without using a mounting bracket, use one or two of the provided tilt plates, which will allow you to tilt the detector upward or downward and thus its field-of-view accordingly.
Use more than one tilt plate to achieve a greater vertical incline of the detector and thus its field-of-view accordingly.
Each tilt plate tilts the detector’s vertical field-of-view by 5°. So if you mount the detector with two tilt plates, the detector’s field-of-view will be tilted by 10°.
If you mount the detector with three tilt plates, the detector’s field of view will be tilted by 15°.
All detectors’ features can be adjusted by a Remote Control (Obtained separately).
Remote Controlled
Detector’s features can be remotely programmed and adjusted by our unique and friendly Remote Control so no longer need to climb a ladder, disassemble the detectors and make manual adjustments whenever needed.
Moreover, technical functionality data and detection evens history of the detector can be displayed on the Remote Control screen.
The Remote Control can be purchased separately.
Partial list of possible programming and options by using Remote Control RM-1:
Power Supply | 12V DC |
---|---|
Current Drain | 45 mA (Maximum) |
Alarm Contacts Endurance | (N.C.) 24V DC / 100 mA |
Masking Contacts Endurance | (N.C.) 24V DC / 100 mA |
Tamper Switch Contacts | (N.C.) 24V DC / 100 mA |
Warm-Up Time | 60 Seconds |
Alarm Time | 2 Seconds (Programmable from 1 to 99 Seconds by the optional Remote Control). |
Response Time To Masking | 30 Seconds (Max.) |
Operating Temperature | (-)20°C ~ 60°C |