Introduction
OUT-LOOK detector provides highly reliable movement detection and ensures excellent protection against any attempt to disable its operation by blocking (masking) its near field-of-view or when the detector has been covered, whether the alarm system is Armed or Disarmed (“Anti-masking”).
OUT-LOOK detector equipped with two lenses. One lens in its front while the other is at its lower part.
By adjusting the lower lens internal mechanism, it is possible to set the pet immunity (creep zone) detection sensitivity.
All detectors’ features can be adjusted by a Remote Control (Obtained separately).
Detector’s features can be remotely programmed and adjusted by our unique and friendly Remote Control so no longer need to climb a ladder, disassemble the detectors and make manual adjustments whenever needed.
Moreover, technical functionality data and detection evens history of the detector can be displayed on the Remote Control screen.
The Remote Control can be purchased separately.
Partial list of possible programming and options by using Remote Control RM-1:
Power Supply | 12V DC |
---|---|
Current Drain | 45 mA (Maximum) |
Alarm Contacts Endurance | (N.C.) 24V DC / 100 mA (Max) |
Masking Contacts Endurance | (N.C.) 24V DC / 100 mA (Max) |
Tamper Switch Contacts | (N.C.) 24V DC / 100 mA (Max) |
Warm-Up Time | 60 Seconds |
Alarm Time | 2 Seconds (Programmable from 1 to 99 Seconds by the optional Remote Control). |
Response Time To Masking | 30 Seconds (Max.) |
Anti-Masking Relay Activation Time | As long as Masking persists (at least 2 seconds) |
Operating Temperature | (-)37°C ~ 70°C (-4°F ~ 158°F) |